Cooling Media 1920 E. Encanto Drive Tempe, AZ, 85281 P 480-968-9550 F 480-968-9555 info@coolingmedia.com |

Cooling Media 1920 E. Encanto Drive Tempe, AZ, 85281 P 480-968-9550 F 480-968-9555 info@coolingmedia.com |
GLASdek® evaporative media is made from a flame retardant material fortified with special rigidifying agents.
The cross fluted, unequal angle pad design induced highly turbulent mixing of air and water for optimum heat and moisture transfer.
This unique design also functions to continually direct more water to the air entering face of the pad, where the more intense evaporation occurs, further enhancing the operating efficiency of the pad.

High Cooling Efficiency
Exceptional cooling rates are achieved due to the design, manufacturing and materials used in GLASdek®.
High Face Velocity
The shallower angle of Munters® unequal flute design allows high velocity air to travel through the pad without water droplet carryover.
Self-Cleaning Design
Munters® GLASdek® resists the clogging caused by dust or sand. The water flushes dirt and debris from the surface of the pad. The water is directed toward the air entering face of the pad by design, where it is needed most.
Low Pressure Drop
Simple to Maintain
Fire Rated UL®900, Class II for safety
Water Distribution
Water flow needed is based on the depth of the media used. GLASdek® requires 1.5 gallons per minute of water per square foot of horizontal (top) pad surface area. For installations that have intense evaporation or pad walls taller than 72", an additional 10-20% of water may be required.
Supply
The gutter and sump should be sized to supply the system with enough water to operate at its maximum flow rate and not overflow when the system is shut down.
Protective Edge Coating
TUFedg® algae-resistant edge coating is available for all sizes of GLASdek® evaporative media for longer pad life and easier cleaning.
Distribution Pads
2" or 3" distribution pads disperse water laterally and evenly across the top of the pad. These specially designed pads are also protected with Munters' patented edge treatment.
Scale
Mineral deposits can be minimized by maintaining a continuous water bleed-off, or by periodically dumping the sump. The exact amount will depend on the pH and hardness of the supply water, and Munters® can assist you by recommending individual bleed-off rates.
Note: Fractional timers should not be used. These timers do not enhance the performance of a cooling pad and actually contribute to the development of scale.
Algae
If algae is allowed to grow freely on GLASdek® it may eventually clog the passages and inhibit the flow of air. This increases the static pressure and reduces the efficiency of the pad. Algae build up can be controlled by early implementation of simple maintenance techniques. Munters® maintenance bulletins provide information to help maximize the efficiency and life of GLASdek®.
You can request a quote at any time or contact us for assistance.
Note: The data and suggestions contained herein are based on information Munters® believes to be reliable. They are offered in good faith, but without guarantee, as conditions and methods of use are beyond our control. We recommend that the prospective user determine the suitability of our products and suggestions before adopting them on a commercial sale.